13

SR

/200

/300

IP rating

IP68

Duty

Continuous S1

Minimum level of the liquid to be pumped (mm)

150

Maximum immersion depth (m)

20

Max number of starts per hour

40

Max temperature of the liquid pumped (°C)

45

PH of the liquid pumped

6 - 10

Maximum sand content (g/m

3

)

50

Suitable for inverter drive

Three-phase versions only

Not suitable to operate horizontally

APPLICATION FEATURES

SR

/200

/300

Discharge, motor cover and central body

Brass OT58

External casing, handle, motor casing,

bolts and nuts

Stainless Steel AISI304

Shaft

Stainless Steel AISI420B

Impellers and diffusers

Noryl®reinforced with fibre-glass certified for drinkable water and Stainless Steel

AISI304 wear rings

Foot

ABS

Mechanical Seal

Graphite and Alumina

Elastomers

NBR rubber

Cable

PVC ACS AD8

(for permanent immersion

in drinking water)

MATERIALS