Table of Contents Table of Contents
Previous Page  160 / 170 Next Page
Information
Show Menu
Previous Page 160 / 170 Next Page
Page Background

160

CHARACTERISTICS

IP rating IP55

Ambient Temperature -5/+40 °C

N° 1 facility for wiring a pump controller (float switch, pressure switch,

temperature sensor etc.)

N° 3 facilities for wiring level probes that can also be used with one

or two float switches

MAIN COMPONENTS

Plastic panel

Opening interlocked

Run contactor

Low-voltage auxiliary circuit (24 V) with fuses

Thermal relay for motor protection

Set of fuses for motor protection

Electronic level control by means of a microprocessor

Hand - off - auto selector switch

Led lights for power and motor running, thermal cut-out and level cut-out

Type

Code

Approx. Power

A min A max

Dimensions

hp

kW

mm

Single-phase 230 V 50 Hz

AM 20 CL

02080025 2

1,5

9 13

220 x 300 x 120

AM 30 CL

02080030 3

2,2

12 18

Three-phase 400 V 50 Hz

AT 55 CL

02081030 5,5

4

9 13

220 x 300 x 120

AT 75 CL

02081035 7,5 5,5 12 18

AT 125 CL

02081040 10 - 12,5 7,5 - 9,2 17 25

AT 150 CL

02081045 15

11 22 32

CHARACTERISTICS

IP rating IP55

Ambient Temperature -5/+40 °C

N° 3 facilities for wiring a start - stop alternate-duty-assist device

(float switch, pressure switch, etc.)

N° 1 facility for maximum level alarm device

N° 1 Volt-free facility for alarm device

MAIN COMPONENTS

Plastic panel

Opening interlocked

Low-voltage auxiliary circuit (24 V) with fuses

Run contactors

Thermal relays to protect the motors (in case of intervention,

the stand-by pump is immediately turned ON)

Set of fuses for motor

Electronic circuit with microprocessor to control the alternate

or simultaneous run of the electric pumps

Hand - off - auto selector switch

Led lights for: run P1 and P2 - thermal cut-out P1 and P2

ACCESSORIES

Power failure alarm

Type

Code

Approx. Power

A min A max

Dimensions

hp

kW

mm

Single-phase 230 V 50 Hz

P2 BPA2 4

ZP2BPA2/1

0,5 0,37 2,5 4

300 x 380

x 120

P2 BPA2 6

0,75 - 1 0,55 - 0,75 4 6,3

P2 BPA2 10

1,5

1,1

7 10

P2 BPA2 13

2

1,5 9 13

Three-phase 400 V 50 Hz

P2 BPTA2 2

ZP2BPTA2/1

0,5 0,37 1,2 1,9

300 X 380

X 120

P2 BPTA2 2,5

0,75 0,55 1,6 2,5

P2 BPTA2 4

1 - 1,5 0,75 - 1,1 2,5 4

P2 BPTA2 6

2 - 3 1,5 - 2,2 4 6,3

P2 BPTA2 10

4,5

3,4 7 10

Control and protection panels

AM - AT - Direct-on line starters for single and three-phase pumps with level control

P2 BPA2 - P2 BPTA2 - Direct on line electromechanical single/three-phase starters for 2 electric pumps