CHARACTERISTICS

IP rating IP40

Ambient Temperature -5/+40 °C

N° 2 facilities for wiring a pump controller (float switch, pressure switch,

temperature sensor etc.)

N° 2 facilities for wiring start - stop float switches

N° 1 facility for wiring a pressure transducer 4÷20 mA 0÷10 bar

MAIN COMPONENTS

Steel-sheet control panel

Opening interlocked

Low-voltage auxiliary circuits (24V) with fuses

Inverter with display, setting keyboard and internal fan

Set of fuses to protect the inverter

Hand - off - auto selector switches.

In Hand: using constant frequency (50 Hz) via pressure switch,

float switch, etc.

In Auto: using variable frequency (30÷50 Hz) via pressure transducer

4÷20 mA 0÷10 bar

Lamps for: power - run - alarm - level cut-out

ACCESSORIES

Pressure trasducer

Type

Code

Approx. Power

A max

Dimensions

hp

kW

mm

Single-Phase line 230 V 50 Hz - Three-phase motor 230 V 50 Hz

ATI 230 10

02077010 1

0,75 4,2

300 x 400 x 200

ATI 230 20

02077020 1 - 2 0,75 - 1,5 6,8

ATI 230 30

02077030 2 - 3 1,5 - 2,2 9,6 400 x 600 x 250

Three-phase line 400 V 50 Hz - Three-phase motor 400 V 50 Hz

ATI 400 10

02078010 1

0,75 2,2

300 x 400 x 200

ATI 400 20

02078020 1 - 2 0,75 - 1,5 3,7

ATI 400 30

02078030 2 - 3 1,5 - 2,2 5,3

ATI 400 40

02078040 3 - 4

2,2 7,2

400 x 600 x 250

ATI 400 55

02078050 4 - 5,5 3 - 4

9

ATI 400 75

02078060 5,5 - 7,5 4 - 5,5 12

ATI 400 100

02078070 7,5 - 10 5,5 - 7,5 15,5

CHARACTERISTICS

IP rating IP55

Ambient Temperature -5/+40 °C

N° 1 facility for wiring a pump controller (float switch, pressure switch,

temperature sensor etc.)

N° 2 facilities for wiring start – stop float switches

N° 3 facilities for wiring level probes

MAIN COMPONENTS

Steel-sheet control panel

Opening interlocked

Low-voltage auxiliary circuits (24V) with fuses

Set of fuses to protect the motor

Hand - off - auto selector switch

Lamps for: power - run - thermal cut-out – level cut-out

Type

Code

Approx. Power

A min A max

Dimensions

hp

kW

mm

Three-phase 400 V 50 Hz

ATRS 10

02079010 7,5 - 12,5 5,5 - 9,2 12 25 300 x 400 x 200

ATRS 20

02079020 15 - 20 11 - 15 14 32

400 x 600 x 250

ATRS 25

02079030 25 18,5 23 45

ATRS 35

02079050 30 - 35 22 - 26 30 60

ATRS 40

02079060 40

30 37,5 75

500 x 700 x 250

ATRS 50

02079070 50

37 42,5 85

ATRS 60

02079080 60

45 60 115

ATRS 75

02079090 75

55 70 142 600 x 800 x 300

ATI - Three-phase Inverter starters

ATRS - Three-phase soft starters