Control and protection panels

ATS - Direct-on-line electromechanical three-phase starters for electric pumps Semisom/80

AT2S - Direct-on-line electromechanical three-phase starters for 2 electric pumps Semisom/80

CHARACTERISTICS

IP rating IP55

Ambient Temperature -5/+40 °C

N° 1 facility for wiring the humidity probe of the first chamber

N° 1 facility for wiring the temperature sensor

N° 1 facility for wiring a pump controller (float switch, pressure switch,

temperature sensor etc.)

N° 2 facilities for wiring start – stop float switches

N° 1 facility for maximum level float switch

N° 1 facility for 24 V AC alarm device

MAIN COMPONENTS

Steel-sheet control panel

Opening interlocked

Low-voltage (24 V) auxiliary circuits with fuses

Run contactor

Thermal relay for motor protection

Relay to control motor overheating

Set of fuses to protect the motor

Electronic control in case of humidity in the first chamber

Hand - off - auto selector switch

Lamps for: power - run - thermal cut-out - cut-out for motor overheating -

cut-out for humidity in the first chamber - maximum level cut-out

Type

Code

Approx. Power

A min A max

Dimensions

hp

kW

mm

Three-phase 400 V 50 Hz

ATS 55

02082010 3,5 - 5,5 2,6 - 4 7 10

300 x 400 x 150

ATS 100

02082020 7,5 - 10 5,5 - 7,5 12 18

ATS 110

02082030 11

8 17 25

MAIN COMPONENTS

Steel-sheet control panel

Opening interlocked

Low-voltage (24 V) auxiliary circuits with fuses

Run contactors

Thermal relays for motor protection

Relays to control motor overheating

Set of fuses to protect the motor

Electronic control in case of humidity in the first chambers

Hand - off - auto selector switches

Electronic circuit with microprocessor to control the alternate

or simultaneous run of the electric pumps

Lamps for: power - pump 1 - pump 2 - thermal cut-out - cut-out for motor

overheating - cut our for humidity in the first chamber

CHARACTERISTICS

IP rating IP55

Ambient Temperature -5/+40 °C

N° 2 facilities to wire the humidity probes of the first chamber

N° 2 facilities for wiring the temperature sensors

N° 3 facilities for wiring a start - stop alternate-duty-assist device

(float switch, pressure switch, etc.)

N° 1 facility for maximum level alarm device

N° 1 Volt-free facility for alarm device

ACCESSORIES

Power failure alarm

Type

Code

Approx. Power

A min A max

Dimensions

hp

kW

mm

Three-phase 400 V 50 Hz

AT2S 55

02082110 3,5 - 5,5 2,6 - 4 7 10

400 x 600 x 200

AT2S 100

02082120 7,5 - 10 5,5 - 7,5 12 18

AT2S 110

02082130 11

8 17 25